TG-170 Series HTHP Filter Presses
TG-170 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Model and Specifications
|
Name |
HTHP Filtration |
||||
|
Model |
TG-170-00 |
TG-170-01 |
TG-170-02 |
TG-171-01 |
TG-171-02 |
|
Dimensions (cm) |
15×20×53cm |
20×20×57cm |
26×25×56cm |
21×31×76cm |
35×31×76cm |
|
Weight (kg) |
21kg |
24kg |
26kg |
40kg |
45kg |
|
Input Voltage |
AC220V±5% 50Hz |
||||
|
Power (KW) |
0.4W |
|
|
1KW |
1.5KW |
|
Maximum Temperature(℃) |
150℃ |
232℃ |
|||
|
Maximum Pressure (MPa) |
4.2MPa |
7.1MPa |
|||
|
Maximum Returning Pressure (MPa) |
0.7MPa |
3.5MPa |
|||
|
Mesh Area (cm2) |
22.6cm2 |
||||
|
Cup Capacity (ml) |
175ml |
500ml |
|||
|
Name |
HTHP Dynamic Filtration |
Return Pressure Receiver |
|
|
Model |
TG-172-50 |
TG-170-20 |
TG-171-20 |
|
Dimensionss (cm) |
46×25×78cm |
10×6×13cm |
10×6×16cm |
|
Weight (kg) |
75kg |
1.5kg |
1.9kg |
|
Power Supply |
AC220V±5% 50Hz |
— |
— |
|
Power(KW) |
1.2W |
— |
— |
|
Speed Adjustable Range (r/min) |
0~800 r/min |
— |
— |
|
Maximum Temperature of Static Filtration (℃) |
232℃ |
— |
— |
|
Maximum Temperature of Dynamic Temperature Filtration (℃) |
150℃ |
— |
— |
|
Maximum Pressure (MPa) |
7.1MPa |
0.7MPa |
3.5MPa |
|
Maximum Return Pressure (MPa) |
3.5MPa |
— |
— |
|
Mesh Area (cm2) |
22.6cm2 |
— |
— |
|
Cup Capacity (ml) |
500ml |
— |
— |
TG-70 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Product detail pictures:

Related Product Guide:
Shenyang Taige’s Product Played a Part in Shengli Oilfield’s Projects
Mobile Cementing Laboratory for Oil Well Cement Test Instruments
We are also specializing in improving the things management and QC method in order that we could retain terrific edge inside the fiercely-competitive small business for Super Lowest Price Matcha Mud Mask - High pressure,High temperature filtration – Taige, The product will supply to all over the world, such as: Portugal , Istanbul , Southampton , With the development and enlargement of mass clients abroad, now we've set up cooperative relationships with many major brands. We've our own factory and also have many reliable and well-cooperated factories in the field. Adhering to the "quality first, customer first, We are provideing high-quality, low-cost items and first-class service to customers. We sincerely hope to establish business relationship with customers from all over the world on the basis of quality, mutually benefit. We welcome OEM projects and designs.
This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!