Annulus-microfracture Gas-migration Apparatus Introduction This apparatus is tested the effect of the adhesive force of cement annulus and cement annulus vs. outer side of oil tube and inner side of annular tube in the condition of simulating downhole change environment.The instrument can stimulate the following environment change:the voltage change inside the oil tube the temperature change of the bottom pressure alternate change of the pressure at the top and the bottom of cement ann...


Product Detail

Product Tags

Related Video

Feedback (2)

Bear "Customer first, High quality first" in mind, we perform closely with our consumers and provide them with efficient and experienced services for Chemical Defoamer , Slurry Tester , Filter Equipment , For more information, please contact us as soon as possible!
Special Design for Walk-In Curing Room - Annulus-microfracture Gas-migration – Taige Detail:

Annulus-microfracture Gas-migration Apparatus 

Introduction 

This apparatus is tested the effect of the adhesive force of cement annulus and cement annulus vs. outer side of oil tube and inner side of annular tube in the condition of simulating downhole change environment.

The instrument can stimulate the following environment change:

  1. the voltage change inside the oil tube 
  2. the temperature change of the bottom pressure 
  3. alternate change of the pressure at the top and the bottom of cement annular 
  4. alternate change of the pressure of oil tube and ground  
  5. the change of the compressing force for oil tube
  6. the change of the drawing force for oil tube

Configurations

  1. operation and control part
  2. curing part
  3. vessel
  4. data acquisition system

10

TG-5002

840*750*1700mm(1280kg)

Specifications 

Outer diameter of inner tube: φ177.8mm

Inner diameter of outer tube: φ245mm

Pressure of inner tube: 0~70MPa (pressure controlled) 

Pressure of outer tube: 0~70MPa (pressure controlled) 

Pressure of air layer: 0~12MPa (pressure controlled) 

Pressure of the top and the bottom of cement annular: 0~70MPa (pressure controlled) 

Temperature range: 200℃ (temperature controlled) 

Drawing force: 0~10000kg (force controlled)

Compressing force: 0~10000kg (force controlled) 


Product detail pictures:

Special Design for Walk-In Curing Room -
 Annulus-microfracture Gas-migration – Taige detail pictures


Related Product Guide:
HTHS High Density Cementing System
Investec Asset Management North America Decreased Tim Participacoes Sa (TSU) Holding; SIKA AG ORDINARY SHARES (SKFOF) SI Increased By 26.7% | Organic Chemicals Additives

To get the stage of realizing dreams of our employees! To build a happier, more united and much more skilled crew! To reach a mutual benefit of our prospects, suppliers, the society and ourselves for Special Design for Walk-In Curing Room - Annulus-microfracture Gas-migration – Taige, The product will supply to all over the world, such as: Uganda , Qatar , Thailand , Our company insists on the purpose of "takes service priority for standard, quality guarantee for the brand, do business in good faith, to provide professional, rapid, accurate and timely service for you". We welcome old and new customers to negotiate with us. We will serve you with all sincerity!
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Audrey from London - 2015.09.23 17:37
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Janet from Cancun - 2016.02.14 13:19

    Related Products

    WhatsApp Online Chat !