Original Factory Hydrostatic Test Pump - High pressure,High temperature filtration – Taige
Original Factory Hydrostatic Test Pump - High pressure,High temperature filtration – Taige Detail:
TG-170 Series HTHP Filter Presses
TG-170 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Model and Specifications
|
Name |
HTHP Filtration |
||||
|
Model |
TG-170-00 |
TG-170-01 |
TG-170-02 |
TG-171-01 |
TG-171-02 |
|
Dimensions (cm) |
15×20×53cm |
20×20×57cm |
26×25×56cm |
21×31×76cm |
35×31×76cm |
|
Weight (kg) |
21kg |
24kg |
26kg |
40kg |
45kg |
|
Input Voltage |
AC220V±5% 50Hz |
||||
|
Power (KW) |
0.4W |
|
|
1KW |
1.5KW |
|
Maximum Temperature(℃) |
150℃ |
232℃ |
|||
|
Maximum Pressure (MPa) |
4.2MPa |
7.1MPa |
|||
|
Maximum Returning Pressure (MPa) |
0.7MPa |
3.5MPa |
|||
|
Mesh Area (cm2) |
22.6cm2 |
||||
|
Cup Capacity (ml) |
175ml |
500ml |
|||
|
Name |
HTHP Dynamic Filtration |
Return Pressure Receiver |
|
|
Model |
TG-172-50 |
TG-170-20 |
TG-171-20 |
|
Dimensionss (cm) |
46×25×78cm |
10×6×13cm |
10×6×16cm |
|
Weight (kg) |
75kg |
1.5kg |
1.9kg |
|
Power Supply |
AC220V±5% 50Hz |
— |
— |
|
Power(KW) |
1.2W |
— |
— |
|
Speed Adjustable Range (r/min) |
0~800 r/min |
— |
— |
|
Maximum Temperature of Static Filtration (℃) |
232℃ |
— |
— |
|
Maximum Temperature of Dynamic Temperature Filtration (℃) |
150℃ |
— |
— |
|
Maximum Pressure (MPa) |
7.1MPa |
0.7MPa |
3.5MPa |
|
Maximum Return Pressure (MPa) |
3.5MPa |
— |
— |
|
Mesh Area (cm2) |
22.6cm2 |
— |
— |
|
Cup Capacity (ml) |
500ml |
— |
— |
TG-70 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Product detail pictures:

Related Product Guide:
Iran Oil Show 2024, Shenyang Taige Oil Equipment will attend
Mixing and Dust Reduction in a Horizontal Plow Mixer | Oil Field Cementing Additives
Trustworthy good quality and excellent credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality first, buyer supreme" for Original Factory Hydrostatic Test Pump - High pressure,High temperature filtration – Taige, The product will supply to all over the world, such as: Bangladesh , Russia , Serbia , Corporate goal: Customers' satisfaction is our goal, and sincerely hope to establish long-terms stable cooperative relations with customers to jointly develop the market. Building brilliant tomorrow together!Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.
The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.





