Newly Arrival High Speed Concrete Mixer - High pressure,High temperature filtration – Taige
Newly Arrival High Speed Concrete Mixer - High pressure,High temperature filtration – Taige Detail:
TG-170 Series HTHP Filter Presses
TG-170 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Model and Specifications
|
Name |
HTHP Filtration |
||||
|
Model |
TG-170-00 |
TG-170-01 |
TG-170-02 |
TG-171-01 |
TG-171-02 |
|
Dimensions (cm) |
15×20×53cm |
20×20×57cm |
26×25×56cm |
21×31×76cm |
35×31×76cm |
|
Weight (kg) |
21kg |
24kg |
26kg |
40kg |
45kg |
|
Input Voltage |
AC220V±5% 50Hz |
||||
|
Power (KW) |
0.4W |
|
|
1KW |
1.5KW |
|
Maximum Temperature(℃) |
150℃ |
232℃ |
|||
|
Maximum Pressure (MPa) |
4.2MPa |
7.1MPa |
|||
|
Maximum Returning Pressure (MPa) |
0.7MPa |
3.5MPa |
|||
|
Mesh Area (cm2) |
22.6cm2 |
||||
|
Cup Capacity (ml) |
175ml |
500ml |
|||
|
Name |
HTHP Dynamic Filtration |
Return Pressure Receiver |
|
|
Model |
TG-172-50 |
TG-170-20 |
TG-171-20 |
|
Dimensionss (cm) |
46×25×78cm |
10×6×13cm |
10×6×16cm |
|
Weight (kg) |
75kg |
1.5kg |
1.9kg |
|
Power Supply |
AC220V±5% 50Hz |
— |
— |
|
Power(KW) |
1.2W |
— |
— |
|
Speed Adjustable Range (r/min) |
0~800 r/min |
— |
— |
|
Maximum Temperature of Static Filtration (℃) |
232℃ |
— |
— |
|
Maximum Temperature of Dynamic Temperature Filtration (℃) |
150℃ |
— |
— |
|
Maximum Pressure (MPa) |
7.1MPa |
0.7MPa |
3.5MPa |
|
Maximum Return Pressure (MPa) |
3.5MPa |
— |
— |
|
Mesh Area (cm2) |
22.6cm2 |
— |
— |
|
Cup Capacity (ml) |
500ml |
— |
— |
TG-70 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Product detail pictures:

Related Product Guide:
Grant Oil Show, Expect your visit, Shenyang Taige Oil Equipment
API Specification for Oil-well Cements
With a complete scientific quality management system, good quality and good faith, we win good reputation and occupied this field for Newly Arrival High Speed Concrete Mixer - High pressure,High temperature filtration – Taige, The product will supply to all over the world, such as: Turin , Croatia , Zurich , As the world economic integration bringing challenges and opportunities to the xxx industry, our company , by carrying on our teamwork, quality first, innovation and mutual benefit, are confident enough to supply our clients sincerely with qualified merchandise, competitive price and great service, and to build a brighter future under the spirit of higher, faster, stronger with our friends together by carrying on our discipline.
The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.