Newly Arrival High Speed Concrete Mixer - High pressure,High temperature filtration – Taige
Newly Arrival High Speed Concrete Mixer - High pressure,High temperature filtration – Taige Detail:
TG-170 Series HTHP Filter Presses
TG-170 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Model and Specifications
|
Name |
HTHP Filtration |
||||
|
Model |
TG-170-00 |
TG-170-01 |
TG-170-02 |
TG-171-01 |
TG-171-02 |
|
Dimensions (cm) |
15×20×53cm |
20×20×57cm |
26×25×56cm |
21×31×76cm |
35×31×76cm |
|
Weight (kg) |
21kg |
24kg |
26kg |
40kg |
45kg |
|
Input Voltage |
AC220V±5% 50Hz |
||||
|
Power (KW) |
0.4W |
|
|
1KW |
1.5KW |
|
Maximum Temperature(℃) |
150℃ |
232℃ |
|||
|
Maximum Pressure (MPa) |
4.2MPa |
7.1MPa |
|||
|
Maximum Returning Pressure (MPa) |
0.7MPa |
3.5MPa |
|||
|
Mesh Area (cm2) |
22.6cm2 |
||||
|
Cup Capacity (ml) |
175ml |
500ml |
|||
|
Name |
HTHP Dynamic Filtration |
Return Pressure Receiver |
|
|
Model |
TG-172-50 |
TG-170-20 |
TG-171-20 |
|
Dimensionss (cm) |
46×25×78cm |
10×6×13cm |
10×6×16cm |
|
Weight (kg) |
75kg |
1.5kg |
1.9kg |
|
Power Supply |
AC220V±5% 50Hz |
— |
— |
|
Power(KW) |
1.2W |
— |
— |
|
Speed Adjustable Range (r/min) |
0~800 r/min |
— |
— |
|
Maximum Temperature of Static Filtration (℃) |
232℃ |
— |
— |
|
Maximum Temperature of Dynamic Temperature Filtration (℃) |
150℃ |
— |
— |
|
Maximum Pressure (MPa) |
7.1MPa |
0.7MPa |
3.5MPa |
|
Maximum Return Pressure (MPa) |
3.5MPa |
— |
— |
|
Mesh Area (cm2) |
22.6cm2 |
— |
— |
|
Cup Capacity (ml) |
500ml |
— |
— |
TG-70 series high temperature and pressure fluid loss is a special device which is mainly used to measure drilling fluids loss and later produce it into the mud pies. It is mainly made up of one scyphus, one pressure hose, one filter gauze, and strain of the base cover. The scyphus is used to put drilling fluids sample. The instrument is made up of stainless scyphus, heating jacket, PDI auto constant temperature controller, stainless housing, outside heating insulating layer. The use of the period is long. The precision is high, close error. It is safe and easy to operate, ant the data is precious. It has already been used in all kinds of oilfield, scientific institute, lab and other departments.
Product detail pictures:

Related Product Guide:
Investec Asset Management North America Decreased Tim Participacoes Sa (TSU) Holding; SIKA AG ORDINARY SHARES (SKFOF) SI Increased By 26.7% | Organic Chemicals Additives
ADIPEC 2024- Cementing test equipment and chemicals
Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as theory of "quality the basic, have faith in the initial and administration the advanced" for Newly Arrival High Speed Concrete Mixer - High pressure,High temperature filtration – Taige, The product will supply to all over the world, such as: Mauritius , Serbia , Istanbul , Our company always committed to meet your quality demand, price points and sales target. Warmly welcome you open the boundaries of communication. It is our great pleasure to service you if you need a trusted supplier and value information.
The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.