Good quality Residual Chlorine Analyzer - Bench-Top Consistometer – Taige
Good quality Residual Chlorine Analyzer - Bench-Top Consistometer – Taige Detail:
Bench-Top Consistometer/
Function/
Bench-Top Consistometers are small enough to be set on a normal laboratory workbench and easy to use. The unit’s functional, compact design is made possible by the use of high-strength alloys in the pressure vessel. The rotating slurry container is equipped with rotational paddle assembly per API Specification. The pressure vessel is capable of withstanding the high pressures and temperatures to run tests in accordance with most API Spec 10 schedules. The TG-7716 and TG-7720 are designed to be versatile and extremely accurate. They can be used in remote field locations, mobile labs, and offshore platforms where space is limited.
Bench-Top Consistometers Model TG-7716/7720 are specifically designed to measure the thickening time of cement slurries in strict accordance with API 10 specification. The units can be used to prepare slurries for the measurement of free water content,viscosity, fluid loss and rheological properties.
The Consistometer can be used to measure temperature and pressure accordance with API 10 specification’s recommended data or required data. The slurry cap is rotated at a constant speed of 150 rpm to circulate the slurry.
Model TG-7720 has wide pressure and temperature operation ranges up to 137MPa and 204℃. They are supplied with a magnetic drive for the rotational drive of the slurry cup as standard equipment.
Model:TG-7716
Dimension:670*360*570mm (89kg)
Model/
| Model | Dimension (mm) | Weight | Remark |
| TG-7716 | 670*360*570 | 89kg | |
| TG-7720 | 670*360*570 | 89kg | |
| TG-7718 | 670*360*570 | 89kg | Without potentiometer |
Benefits/
In Strict Compliance to API Spec 10/
Digital Temperature Indicator /
Pressure Vessel Forged from Special Alloy/
Model TG-7720 max pressure is 137MPa/ TG-7720
Model TG-7720 max temperature is 204℃/ TG-7720
Model TG-7716 max pressure is 120MPa/ TG-7716
Model TG-7716 max temperature is 177℃/ TG-7716
Rugged design. Easy operation.
High Wattage Heater/
Magnetic Drive System to reduce maintenance/
Cooling Jacket on Pressure Vessel for rapidly cool/
Recorder records the temperature and viscosity value/
Specifications/
Heater Power/ : 3KW
Rotating Speed/ : 150r/min
Consistency Range/ : 0~100Bc
Pressure Medium/ : white mineral oil
Viscosity Resolution/ : 1Bc
Input voltage/ : 220VAC 50Hz
Operating temperature/ : 0~50℃
Compressed Air/ : 0.5-0.8MPa
Cooling Water Pressure : 02-0.6MPa
Model: TG-7716
670*360*570mm (89kg)
Product detail pictures:

Related Product Guide:
Arup and CLS Architetti 3D printing concrete house for Milan Design Week | Oil Field Cementing Additives
Global Oil and Gas Chemicals Market 2018 growth Worldwide Forecast to 2025 | Stirred Fluid Loss Cell
We always get the job done to be a tangible staff to ensure that we can easily offer you the best high-quality and the greatest value for Good quality Residual Chlorine Analyzer - Bench-Top Consistometer – Taige, The product will supply to all over the world, such as: Montreal , Norway , Cannes , We've got sufficient experience in producing products according to samples or drawings. We warmly welcome customers from home and abroad to visit our company, and to cooperate with us for a splendid future together.
This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.